106 SEBU8524
Maintenance Section
Automatic Lubrication Grease Tank - Fill
i02695981
Autom atic Lubrication Grease
Tank - Fill
(If Equipped)
SMCS Code: 75
40-544-TNK
If the yellow LED on the signal lamp is illuminated,
the minimum
grease level in the reservoir has been
reached.
•
Ensure that
the filler hose is primed with grease in
order to prevent air from being introduced in the
grease reservoir.
g01074471
Illustration 115
Location of the coupling on the lubrication pum p
•
Remove the dust cap from the coupling for the filler.
•
Carefully clean the coupling for the filler and the
coupling on the filler hose. The coupler for the filler
hose is supplied with each Autolube system.
•
Fix the filler hose on the coupling for the filler.
g01076025
I
llustration 116
The maximum leve l mark on the lubrication pum p
•
Fill the reservoir up to the maximum level that is
indicatedonthereservoir.
•
Remove the fille
rhoseandfit the dust cap.
•
Place the filler hose back in the hose's proper
place in order
to ensure that the coupling of the
filler hose remains clean.
Note: Every 5
00 service hours replace the filter or
every 500 service hours clean the filter for the filler
on the lubrication pump. The filter is behind the
connector o
n the reservoir.
Note: If the pumping action seems to go heavy,
check the fil
ter behind the coupling for the filler on the
lubrication pump. Gently clean the filter or replace
the filter.Ifthefilter is damaged, the filter must be
replaced.
Note: If too much grease is pumped into the reservoir,
the surplu
s grease will exit the vent at the side of the
lubrication pump. Any air that is introduced during the
filling procedure will also escape via this route.
Note: Due to the slow capability of a hand held
grease gun, the use of a grease gun is not
recommen
dedinordertofill the reservoir.
Periodi
c Checks
•
Check the grease level in the reservoir. Refill the
reservo
ir on time.
•
Check that the signal lamp is functioning.
•
Check that the duty cycle that is indicated on the
signal lamp is correct for the operating conditions.
•
Check the lubrication pump for damage and check
the lubrication pump for leakage.
•
Check the grease lines for damage and check the
grease lines for leakage.
•
Check the conditions of the grease points that
are served by the system. Sufficient fresh grease
shou
ld be present.
•
Check the operation of the system. Perform a
cyc
le test. Refer to System Operation, Testing and
Adjusting, RENR6739 for more information.
•
Cle
an the lubrication pump and clean the
surroundings of the lubrication pump.
•
Ev
ery 500 hours replace the filter or every 500
hours clean the filter.
No
te: When you use high pressure water or high
pressure air to clean the machine, do not spray
directly onto the lubrication pump. Water or dirt may
en
ter the lubrication pump through the de-arating
openings.